7.
Figure 2, remove the front and rear tamper assemblies. Also remove the tamper gear and
tamper motor.
6
Remove 2 screws,
End
stop
Guide tab
2
Remove
1
3
4 screws
Pull out both tamper
Remove the BM
assemblies
tamper rack guide
Figure 2 Dismantling the tamper assembly
Repairs/Adjustments
REP 11.30-171
5
Remove
the gear
4
Remove
E-clip
Guide tab
End stop
8.
Figure 3, remove the tamper guide plate from each of the tamper assemblies.
2
Remove the
guide plate
Figure 3 Guide plate removal
Replacement
1.
If the tamper racks were removed from the BM tamper rack guide, perform the following:
a.
Align the guide tabs on both tamper racks with the slots in the BM tamper rack guide.
Refer to Figure 2.
b.
Start both tamper racks into the BM tamper rack guide at the same time. Both
tamper racks must engage with the BM tamper gear simultaneously. To check that
the front and rear tampers are correctly aligned, perform the following:
Fully push in the tampers.
The distance between the end stop on each tamper and the ends of the BM
tamper rack guide should be equal. Refer to Figure 2.
If the distances are different by more than 1mm (0.040 inches). Perform again
step B.
2.
Reverse the removal procedure to replace the BM tamper assembly and tamper 1 motor.
3.
Perform ADJ 11.5-171 Booklet Tamping.
August 2007
4-482
1
Remove
screw and
tamper finger