REP 14.10A Scan Idler Pulleys (32-55 ppm)
Parts List on PL 14.25
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord. Electricity
can cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the CVT glass and document glass, REP 14.6A.
2.
Carefully move the full rate carriage to the left side of the scanner module.
3.
Remove the scan idler pulleys, Figure 1.
NOTE: Figure 1 and Figure 2 show the rear scan idler pulley. The procedure for the front
scan idler pulley is similar.
1
Remove the
E-clip
3
Maintain the tension in the cable and
remove the pulley from the cable loop
Figure 1 Scan idler pulley removal
Repairs/Adjustments
REP 14.10A
Replacement
1.
2
Hold the tension in the cable and
slide the pulley off of the shaft
August 2007
4-572
Reverse the removal procedure to replace the scan idler pulleys. Install the scan idler pul-
leys, Figure 2.
3
Install the E-clip
2
Slide the pulley onto the shaft
Figure 2 Scan idler pulley replacement
1
Maintain the tension in the
cable and place the pulley
in the cable loop
WorkCentre 5687 Family