REP 12.1 OCT Fingers Install
Parts List on PL 12.10
Installation
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
CAUTION
Do not install the OCT fingers on 65 -87 ppm machines.
1.
Remove the OCT, PL 12.10 Item 1.
2.
Remove the right hand cover, PL 8.10 Item 9.
3.
Remove lug 1 and lug 2 from the rear of the right hand cover, Figure 1.
Lug 1 (1st in from the right
Lug 2 (5th in from the right
side of the cover).
side of the cover).
Figure 1 Lug removal
CAUTION
Make sure that the OCT fingers are installed in the correct position. Each of the three fingers is
marked.
4.
Install three OCT fingers on to the exit shaft assembly, Figure 2.
WorkCentre 5687 Family
Finger 1
Right side of cover.
August 2007
4-561
Finger 2
Finger 3
Figure 2 Finger install