Xerox WorkCentre 5687 Series Service Manual page 1587

Table of Contents

Advertisement

REP 14.5A Scanner PWB (32-55 ppm)
Parts List on PL 14.25
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord. Electricity
can cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the CVT glass and document glass, REP 14.6A.
2.
Remove the scanner PWB cover, PL 14.25 Item 1. Release the document size sensor
from the cover, REP 14.3A.
3.
Remove the scanner PWB, Figure 1.
3
Remove the scanner
PWB
Figure 1 Scanner PWB
Replacement
1.
Reverse the removal procedure to replace the scanner PWB.
2.
When re-connecting the ribbon cable to PJ456 ensure that the blue band printed on the
cable faces the front of the machine.
WorkCentre 5687 Family
1
Disconnect all
harnesses
2
Release 4 standoffs
August 2007
4-567
Repairs/Adjustments
REP 14.5A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wc5632fWc5545fWc5675fWc5645fWc5687fWc5655f

Table of Contents