Xerox WorkCentre 5687 Series Service Manual page 1598

Table of Contents

Advertisement

REP 14.13A Scanner Drive Belt (32-55 ppm)
Parts List on PL 14.25
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord. Electricity
can cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
CAUTION
When moving the scan carriages, hold them by the metal parts only, to avoid damaging the
lamp or mirrors.
1.
Remove the outboard scan cable, REP 14.12A.
2.
Figure 1. Remove the scanner motor flywheel.
Bearing
Circlip
Drive shaft
Figure 1 Flywheel removal and component location
3.
Remove the circlip from the outboard end of the scanner drive shaft.
4.
Push the drive shaft inboard and remove the bearing.
5.
Remove the drive belt from the motor shaft.
Repairs/Adjustments
REP 14.13A
Drive belt
1
Loosen 2 allen
screws
2
Remove the
flywheel
August 2007
4-578
6.
Remove the drive belt from the drive shaft.
Replacement
1.
The replacement procedure is the reverse of the removal procedure.
WorkCentre 5687 Family

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wc5632fWc5545fWc5675fWc5645fWc5687fWc5655f

Table of Contents