Mitsubishi Electric MELSEC iQ-R Series User Manual page 77

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Ex.
When MC_Power is used together to the axis 38
MCv_AllPower
PLC READY [Y0]
Enable
M0
ServoON
[Axis38.AxisRef]
Axis
PLC READY [Y0]
Enable
ReadyStatus
ServoON
MCv_AllPower
Enable
ServoON
Busy
MC_Power (Axis38)
Enable
ServoON
ReadyStatus
Status
Axis38.Md.AxisStatus
0: Disabled
Axis87.Md.AxisStatus
0: Disabled
■I/O variable
Input import : At start
Name
Variable name
Axis information
Axis
■Input variables
Import:
: Always
Name
Variable name
Enable
Enable
Servo ON
ServoON
request
■Output variable
Name
Variable name
Executing
Busy
Error
Error
Error code
ErrorID
Busy
MC_Power
Status
ReadyStatus
4: Standstill
4: Standstill
0: Disabled
Data type
Input
Setting range
import
AXIS_REF
Data type
Input
Setting range
import
BOOL
TRUE, FALSE
BOOL
TRUE, FALSE
Data type
BOOL
BOOL
WORD(UINT)
0: Disabled
Default
Description
value
Page 568 Axis variables
Omission
possible
The setting under MCv_AllPower is ignored.
Default
Description
value
FALSE
While Enable input is TRUE, the axis control is
valid.
FALSE
Specifies the servo ON request.
Default
Description
value
FALSE
Indicates that the FB is in execution.
FALSE
When TRUE, it indicates that an error has
occurred in the FB.
0
The error code generated in the FB is returned.
2 AXIS MANAGEMENT FUNCTIONS
75
2.4 Servo ON/OFF