14.5

Required Slave Object

The following shows the setting condition of the slave object when using it as Slave of the single axis synchronization function
block.
Slave object
Target position
Position actual value
Other than the above, Necessary Slave Object Unset Error occurs and it will not start.
14.6

Restrictions

• When Master and Slave are specified to the same axis, the error "Master Axis and Slave Axis No. Duplicated" (error code:
1A3EH) will occur.
• When connecting multiple axes in the single axis synchronization function block, if the master axis whose
MasterValueSource is specified with "1: mcSetValue" or "101: mcLatestSetValue" is specified to Slave of the latter FB, the
error "Master Axis and Slave Axis Cyclic Reference" (error code: 1A3FH) will occur.
Setting
Enabled
14 SYNCHRONOUS CONTROL
Disabled
Disabled
14.5 Required Slave Object