Mitsubishi Electric MELSEC iQ-R Series User Manual page 554

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Error
Error
code
(System/
(Hexad
axis/axes
ecimal)
group)
3403H
System
3404H
System
3405H
System
3406H
System
3407H
System
3408H
System
3409H
System
340AH
System
340BH
System
340DH
System
340EH
System
340FH
System
3410H
System
3411H
System
3412H
System
3413H
System
3414H
System
22 TROUBLESHOOTING
552
22.5 List of Error Codes
Error name
Error detail and cause
Out of Master Axis No.
• The value is out of range for
Range
master axis No.
• Invalid axis No. has been set.
Out of Slave Axis No.
• The value is out of range for
Range
slave axis No.
• Invalid axis No. has been set.
Out of Master Axis 1
• The value is out of range for
No. Range
axis No. of master axis 1.
• Invalid axis No. has been set.
Out of Master Axis 2
• The value is out of range for
No. Range
axis No. of master axis 2.
• Invalid axis No. has been set.
Out of Latch Count
The value is out of range for
Range
RatchCount.
Latch Count Incorrect
RecordCount has not been set
when
RecodeMode=RecordCount,Ring
Buffer.
Out of Touch Probe ID
The value is out of range for
Range
TouchProbeID.
Out of Lower Limit
The value is out of range for
Position Range
FirstPosition.
Out of Upper Limit
The value is out of range for
Position Range
LastPosition.
Out of Compensation
The value is out of range for
Time Range
CompensationTime.
Out of Latch Mode
The value is out of range for
Range
RatchMode.
No Calculation Profile
The calculation profile does not
exist.
Calculation Profile
The value is out of range for Data
Incorrect
or Version.
Calculation Profile
The operation was executed
Operating
during calculation profile
operating.
Calculation Profile Error
The calculation profile is broken,
or the format is incorrect.
Out of Offset Range
Offset exceeds the number of
elements of calculation profile
(file or open area).
Out of Calculation
The value is out of range for
Profile ID Range
ProfileData.ID.Number.
Detection
Operation at
timing (At
error
start/
occurrence
during
control
At startWhen
Not execute FB.
executing FB
At startWhen
Not execute FB.
executing FB
At start
Not execute FB.
When
executing FB
At start
Not execute FB.
When
executing FB
When
Not execute FB.
executing FB
When
Not execute FB.
executing FB
When
Not execute FB.
executing FB
When
Not execute FB.
executing FB
When
Not execute FB.
executing FB
When
Not execute FB.
executing FB
When
Not execute FB.
executing FB
During
The execution of FB is
operation
interrupted.
During
The execution of FB is
operation
interrupted.
During
The execution of FB is
operation
interrupted.
During
The execution of FB is
operation
interrupted.
During
The execution of FB is
operation
interrupted.
At start
• [At start] The FB is not
During
executed.
operation
• [During operation]
Operates with
previous setting value.
Remedy
• Set the value within
the range of 1 to
65535.
• Set the axis No. in
which instance is
created.
• Set the value within
the range of 1 to
65535.
• Set the axis No. in
which instance is
created.
• Set the value within
the range of 1 to
65535.
• Set the axis No. in
which instance is
created.
• Set the value within
the range of 1 to
65535.
• Set the axis No. in
which instance is
created.
Set the value within the
range.
Set RecordCount.
Set the valid touch probe
ID.
Set the value within the
range for probe data.
Set the value within the
range for probe data.
Set the value within the
range of -5.0 to 5.0 [s].
Set the value within the
range for
MC_RECORD_MODE.
Set the existing
calculation profile.
Set the data within the
range.
Operate it when Busy of
FB is FALSE.
Set the calculation
profile for a correct
format.
Set a value which does
not exceed the number
of elements of
calculation profile (file
and open area) in Offset.
Set a value within the
range for
ProfileData.ID.Number.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd78g32Rd78g64Rd78ghvRd78g4Rd78ghwRd78g8 ... Show all

Table of Contents