Mitsubishi Electric MELSEC iQ-R Series User Manual page 553

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Error
Error
Error name
code
(System/
(Hexad
axis/axes
ecimal)
group)
3209H
System
Insufficient AddOn Total
System Memory (RAM)
320AH
System
Insufficient Total
System Memory
(Backup RAM)
320BH
System
Insufficient AddOn
System Memory
(Backup RAM)
320CH
System
Cycle Over
320DH
System
Base System Error
320EH
System
Network Driver Error
3400H
System
Out of Axis No. Range
3401H
System
Axis No. Duplication
Setting
3402H
System
Out of Axis Group No.
Range
Error detail and cause
Detection
timing (At
start/
during
control
Memory that exceeded
At power ON
System.PrConst.Addon_AddonLi
During
braryName.RamSizeMax has
operation
been used.
The total number of
At power ON
System.PrConst.Addon_AddonLi
braryName.BackUpRamSizeMax
for each addon exceeds the total
size of system memory (Backup
RAM).
Memory that exceeded
At power ON
System.PrConst.Addon_AddonLi
During
braryName.BackUpRamSizeMax
operation
has been used.
Arithmetic processing or other
During
fixed scan processing is not
operation
completed within the set cycle.
• Failed to configure label.
At power ON
• Failed to process initial.
Failed to communicate with
At power ON
Motion Module and Network
During
Module.
operation
• The value is out of range for
At start
axis No..
When
• Invalid axis No. has been set.
executing FB
The same axis No. has been set
At startWhen
to master axis and slave axis.
executing FB
• The value is out of range for
When
axis group No..
executing FB
• Invalid axis group has been
set.
Operation at
Remedy
error
occurrence
• [At power ON] The
Please increase
motion system does
System.PrConst.Addon_
not starts.
AddonLibraryName.Ram
• [During operation]
SizeMax.
WDT error occurs if
the function has an
effect on control.
The motion system does
Please set the total
not starts.
number of
System.PrConst.Addon_
AddonLibraryName.Bac
kUpRamSizeMax for
each addon so that it
does not exceed the
total size of system
memory (Backup RAM).
• [At power ON] The
Please increase
motion system does
System.PrConst.Addon_
not starts.
AddonLibraryName.Bac
• [During operation]
kUpRamSizeMax.
WDT error occurs if
the function has an
effect on control.
The axis in operation
Please change the fixed
stops immediately.
scan interval setting of
fixed scan execution
type program to a larger
value.
Please change the
followings to a lager
value.
• "System.PrConst.Syst
emBaseCycle.Cycle"
• "System.PrConst.Oper
ationCycle[1].Cycle"
• "System.PrConst.Buffe
rmemoryRefreshCycle
.Cycle"
The motion system does
• Please install the
not starts.
software again.
• Please write the
program again.
• The motion system
• Please install the
does not starts.
software again.
• The axis in operation
• Please write the
stops immediately.
program again.
Not execute FB.
• Set the value within
the range of 1 to
65535.
• Set the axis No. in
which instance is
created.
Not execute FB.
Set different axis No. to
master axis and slave
axis.
Not execute FB.
• Set the value within
the range of 1 to
65535.
• Set the axis group No.
in which instance is
created.
22 TROUBLESHOOTING
22.5 List of Error Codes