Mitsubishi Electric MELSEC iQ-R Series User Manual page 247

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Output variables
Name
Variable name
Target velocity reached
InVelocity
Executing
Busy
Controlling
Active
Abortion of execution
CommandAborted
Error
Error
Error code
ErrorID
Data type
Default
value
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
WORD(UINT)
0
Description
Indicates that the set velocity that is calculated by
the motion system has reached the target
velocity.
After reaching, the speed is maintained until
Execute turns FALSE or the control is interrupted.
When the target velocity has been changed due
to change at ContinuousUpdate TRUE, it turns
FALSE until the set velocity reaches changed
target velocity.
Indicates that the FB is in execution.
Indicates that the FB is controlling the axis.
Indicates that another FB has aborted the
execution of the FB.
Turns TRUE when this FB is stopped by an error
or this FB is started during an error occurence.
Turns FALSE when Execute is FALSE.
When TRUE, it indicates that an error has
occurred in the FB.
The error code generated in the FB is returned.
For details, refer to the following.
Page 534 List of Error Codes
7 DIRECT CONTROL
7.1 Velocity Control
7
245

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd78g32Rd78g64Rd78ghvRd78g4Rd78ghwRd78g8 ... Show all

Table of Contents