Mitsubishi Electric MELSEC iQ-R Series User Manual page 328

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Operation overview
In MC_SetOverride and MC_GroupSetOverride, AxisName(AxesGroupName).Cd.VelocityOverride and
AxisName(AxesGroupName).Cd.AccelerationOverride of the axis or the axes group can be changed.
MC_SetOverride
VelFactor
AccFactor
1.0
Enable
Enabled
Busy
Error
ErrorID
AxisName.Cd.
VelocityOverride
AcceleratoionOverride
If a value outside the range is set as the override factor, an error will occur in the FB, and subsequent values will not be
imported. To import values again, start up Enable again.
Precautions
• Do not arrange two or more MC_SetOverride and MC_GroupSetOverride in the same axis or the same axes group.
Operation is not guaranteed when two or more of the FBs are arranged.
• In the single axis control, only the override factor set with the axis control data affects. In the axes group control, only the
override factor set with the axes group control data affects.
9 RELEVANT FUNCTIONS TO VELOCITY
326
9.3 Override Function
1.0
0.5
2.0
1.0
0.5
1.0
2.0
-1.0
1.5
Error ID
1.5

Hide quick links: