Mitsubishi Electric MELSEC iQ-R Series User Manual page 535

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Warning
Error
Warning name
code
(System/
(Hexade
axis/axes
cimal)
group)
0F08H
System
Cycle Over Warning
0F09H
System
File Transfer Execution
Request Acquisition
Disabled Warning
0F0AH
System
File Transfer Execution
State Update Disabled
Warning
0F0BH
Axis
Maximum Setting Axis
Number Over Warning
0F0CH
System
Warning Filter Set
Failed Warning
0F0DH
System
Program Setting Import
Disabled Warning
0F0EH
System
Module extended
parameter storage
location warning
*1 Note that the setting range of the upper limit value/lower limit value differs depending on the setting value of
"AxisName.PrConst.RingCount_Enable".
Error detail and cause
Detection
timing (At
start/
during
control
Arithmetic processing or other
During
fixed scan processing is not
operation
completed within the set cycle.
Failed to get address of
At system
"System.Cd.FileTransfer_Execut
start
e".
Failed to get address of
At system
"System.Md.FileTransfer_State".
start
The axis setting which exceeded
At ready
the maximum control axis
ON
number exists.
• Addon MotionEventHist is
At ready
disabled.
ON
• The memory capacity of addon
MotionEventHist is insufficient.
Failed to import the program
At ready
setting.
ON
The project content of the Target
At system
Folder, which differs from that of
start
module extended parameter
storage location setting, was
changed.
Operation at
Remedy
warning occurrence
Continues the operation.
Please change the fixed
scan interval setting of
fixed scan execution
type program to a larger
value.
Please change the
followings to a lager
value.
• "System.PrConst.Syst
emBaseCycle.Cycle"
• "System.PrConst.Oper
ationCycle[1].Cycle"
• "System.PrConst.Buffe
rmemory_RefreshCycl
e.Cycle"
Cannot execute the file
Start the system again.
transfer of the command
label.
Cannot execute the file
Start the system again.
transfer of the command
label.
The axis which is greater
Set the number of
than the mazimum
setting axis within the
setting axis number is
maximum number of
not recognized as the
control axis.
axis. (Md is not updated)
Continues the operation
Please check the
by disabling the filter set.
memory capacity of
Addon MotionEventHist.
Enable addon
MotionEventHist.
The program setting is
Please write the project
not imported.
to user root path.
The written module
Review the module
extended parameter is
extended parameter
not enabled.
storage location setting.