Mitsubishi Electric MELSEC iQ-R Series User Manual page 534

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Warning
Error
code
(System/
(Hexade
axis/axes
cimal)
group)
0D2DH
Axis/Axes
group
0D2EH
Axis/Axes
group
0F00H
System
0F01H
System
0F02H
System
0F03H
System
0F04H
System
0F05H
System
0F06H
System
0F07H
System
22 TROUBLESHOOTING
532
22.4 List of Warning Codes
Warning name
Error detail and cause
Out of Position
The value is out of range for
Command Range
"AxisName(AxesGroupName).Cd
Warning
.Unit_Position".
Out of Speed
The value is out of range for
Command Range
"AxisName(AxesGroupName).Cd
Warning
.Unit_Velocity".
Soft Reboot Disabled
Soft reboot was executed when
Warning
"System.PrConst.SoftRebootEna
ble" is "Disable".
Log File Create
An error has been detected when
Disabled Warning
updating log file.
File Error
• The parameter content is
broken.
• Major version is unsupported.
Position Data History
An error has been detected when
Update Disabled
updating position data history.
Warning
File Transfer Command
Failed to get address of
Acquisition Disabled
"System.Cd.FileTransfer_Comma
Warning
nd".
Event Filter Set Failed
• Addon MotionEventHist is
Warning
disabled.
• The memory capacity of addon
MotionEventHist is insufficient.
File Transfer Parameter
• Failed to access to FRAM
Import Failed Warning
area.
• The compatibility does not exist
in the version of file transfer
parameter.
• The CRC value of file transfer
parameter is abnormal.
Event History
The value is out of range for
Parameter Incorrect
"System.PrConst.EventHistoryM
Warning
otion_Path" and
"System.PrConst.EventHistoryM
otion_Capacity".
Detection
Operation at
timing (At
warning occurrence
start/
during
control
At power
Operates as "pulse".
ON
At ready
ON
At power
Operates as "s".
ON
At ready
ON
When
Not execute soft reboot.
executing
software
reboot
When
The log file is not
executing
created.
file transfer
function
When
The file is not imported.
importing
file
When
The position data history
updating
is not updated.
positioning
data history
file
At system
Cannot execute the file
start
transfer of the command
label.
When
Continues the operation
updating
by the disabled filter
filter setting
setting.
At system
"System.PrConst.FileTra
start
nsfer_LogCapacity"=0,
and continues the
operation by disabled
read/write (00000) of
other acess control.
At system
Operates by the label
start
default value.
Remedy
Set
"AxisName(AxesGroupN
ame).Cd.Unit_Position"
within the range.
Set
"AxisName(AxesGroupN
ame).Cd.Unit_Velocity"
within the range.
Set
"System.PrConst.SoftRe
bootEnable" as
"Enable".
• Delete unnecessary
files to secure the free
capacity.
• Format Target Drive.
• Delete log file.
Please check the
detailed information
(parameter information)
and parameter settings.
• Delete unnecessary
files to secure the free
capacity.
• Format Target Drive.
Delete position data
history.
• Please check the
memory capacity of
addon
MotionEventHist.
Start the system again.
Please check the
memory capacity of
Addon MotionEventHist.
Enable addon
MotionEventHist.
Start the system again.
Set
"System.PrConst.Event
HistoryMotion_Path" and
"System.PrConst.Event
HistoryMotion_Capacity"
within the range.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd78g32Rd78g64Rd78ghvRd78g4Rd78ghwRd78g8 ... Show all