Module Extended Parameters - Mitsubishi Electric MELSEC iQ-R Series User Manual

Motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■sys
File name
/
*.mpk
*.smpk
*.adm
/disabled
■ram
File name
AxisList.json
AxesGroupList.json
AddonInstallInfo.json
/temp
/LOGGING
■lch
File name
abs_axis.bin
■sdc
File name
$MOTPRJ$
autorun.txt
LOGGING**.json

Module extended parameters

The programs and the parameters that are used for controlling the motion system are handled as module extended
parameters. For the target files of the module extended parameter, refer to the following.
Page 502 Storage files
The module extended parameter storage location can be selected from the below by "Module extended parameter storage
location setting" of the module parameter.
Module extended parameter storage
location setting
Motion system (internal memory)
Motion system (SD memory card)
The module extended parameter storage location setting can be overwritten (override) by specifying PATHSET of the root
path using the boot operation file.
• To write the module extended parameter from the engineering tool, specify the writing destination same as
the module extended parameter storage location setting. When the different writing destination is specified,
the written module extended parameter is not enabled.
Useage
Motion software package
Motion module software
Motion module add-on
Temporary disabled file
Useage
Axis instance list
Axes group instance list
Add-on installation information list
Temporary folder
Operation folder for logging
Useage
Axis absolute position data
Useage
File Transfer at boot
Auto logging
Storage location
User drive of motion system (/rom)
SD memory card drive of motion system (/sdc)
Storage file format
Individual file
Individual file
19 FILE CONTROL
19.1 Memory and File
19
503

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd78g32Rd78g64Rd78ghvRd78g4Rd78ghwRd78g8 ... Show all

Table of Contents