NTP 106 — Install a B-2404-P business ONT
Safety information
Read the following safety information before installing the ONT.
Procedure
Use this procedure to install a B-2404-P.
1
Prepare the cables at the site where the B-2404-P will be installed (DLP 100). Also,
locate the power source where the power converter will be installed.
2
Are any of the cables missing?
a
b
3
Locate each missing cable and route them to the B-2404-P as per local practices.
4
Review the connection locations, as shown in Figure
NTP 106-2
November 2013
Danger 1 — Contact the local utility company before you connect the
B-2404-P to the utilities.
Danger 2 — Observe the local and national laws and regulations that
may be applicable to this installation.
Warning — This equipment is ESD sensitive. Proper ESD protections
should be used when connecting or removing the fiber optic cable.
Caution — Keep out of direct sunlight. Prolonged exposure to direct
sunlight can damage the B-2404-P.
Note — Observe the following:
The B-2404-P business ONT should be installed in accordance with
•
the applicable requirements of the NEC or CEC. Local authorities and
practices take precedent when there is conflict between the local
standard and the NEC or CEC.
The B-2404-P business ONT must be installed by qualified service
•
personnel.
See the detailed specifications in the
•
specifications
for the temperature ranges for this ONT.
If yes, go to step 3.
If no, go to step 4.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
B-2404-P detailed
NTP
106-1.
Edition 01
3FE 55873 AAAA TCZZA
ONT Product Information Guide