Ntp 149-1: I-040G-R Ont Connections - Alcatel-Lucent 7302 Information Manual

Intelligent services access manager
Table of Contents

Advertisement

3
Replace the ONT with a new unit:
a
b
4
Connect the Ethernet cables as required to the RJ-45 ports (DLP 101).
5
If required, have approved service personnel who are trained to work with optic
fiber clean the fiber optic connection. See DLP
fiber optic handling, inspection, and cleaning.
6
Connect the SC/APC fiber optic cable (DLP 125).
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
3FE 55873 AAAA TCZZA
Edition 01
ONT Product Information Guide
Figure NTP 149-1: I-040G-R ONT connections
G E 1
G E 2
G E 3
G E 4
Ethernet
Reset
ports (RJ45)
button
Power
button
On a flat surface, such as a desk, substitute a replacement ONT for the old
ONT; go to step 4.
Note — The I-040G-R cannot be stacked with another ONT or with
other equipment. The ONT mounting requirements are:
allow a minimum 100 mm clearance above the top cover
allow a minimum 50 mm clearance from the side vents
do not place any heat source directly above the top cover or below
the bottom cover
On a wall.
i
Slide the old ONT upward and then away from the two mounting screws
until the ONT is free of the wall.
ii
Install the replacement ONT following the wall mounting instructions
for an I-040G-R indoor ONT (DLP 122).
Danger — Fiber optic cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
NTP 149 — Replace an I-040G-R indoor ONT
R E S E T
O N /O F
F
P W R
Power
Fiber optic
connector
connector
134
for more information about
November 2013
23678
NTP 149-3