Connect as many Ethernet cable to the RJ-45 port (DLP 101) as are required.
a
b
c
7
Connect the SC/APC fiber optic cable (DLP 125).
8
Install the UPS according to manufacturer specifications (DLP 110).
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
3FE 55873 AAAA TCZZA
Edition 01
ONT Product Information Guide
NTP 121 — Install an I-010G-B, I-020G-M, or I-040G-B indoor ONT
Figure NTP 121-3: I-010G-B, I-020G-M, or I-040G-B indoor ONT connections
Ethernet ports (RJ-45)
Power connector
Power switch
NTP 121-3
shows the connectors for an I-040G-B indoor ONT. The I-010G-B
For the I-010G-B indoor ONT, connect one cable.
For the I-020G-M indoor ONT, connect two cables.
For the I-040G-B indoor ONT, connect four cables.
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
Note — Observe the following:
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 2 A.
Fiber optic connector
November 2013
NTP 121-5
20385