8
If timeout tone (Frequency: 350Hz, continue) is played, timeout has occurred.
Take the butt set on-hook to enter the second SLID/Password provisioning. Go to
step
9
If error tone (Frequency: 450Hz, 350ms ON and 350ms OFF) is played, the
SLID/Password has not been accepted.
Take the butt set on-hook to enter the second SLID/Password provisioning. Go to
step
10
If dial tone (Frequency: 450Hz, 400ms ON and 4000ms OFF) is played and the LED
is off, the SLID/Password has been accepted.
Take the butt set on-hook to exit the SLID/Password provisioning mode.
11
Reboot the ONT.
12
Connect the fiber optical cable to the ONT.
13
STOP. This procedure is complete.
6.15

XML file configuration data for package C ONTs

For ONTs that are shipped with an XML file already configured, the data that defines
L3 interface and WiFi behavior is pre-configured with default values. Use an XML
file editor to update the file to meet WiFi requirements. See the appropriate unit data
sheet for more information. Table lists the XML file configuration options, sample
XML, and parameter ranges.
Table 6-12 XML file configuration data for package C ONTs
XML parameter
Parameter values
WAN interface configuration
(1 of 6)
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
3FE 55873 AAAA TCZZA
Edition 01
ONT Product Information Guide
The LED should remain static green while inputting the SLID. The interval
between dialing the SLID value must be less than 16 seconds or a timeout will
occur.
Note — Currently, the hexadecimal password only accepts 30 to 39
(ACSII code for "0" to "9").
4
to repeat.