4
Place the I-010G-Q or I-010G-S indoor ONT unit:
a
b
5
Review the connection locations shown in Figures
Figure NTP 127-2: I-010G-Q or I-010G-S indoor ONT connections (power and fiber optic)
6
Connect the Ethernet cable to the RJ-45 port (DLP 101).
7
Connect the fiber optic cable to the ONT with the SC/APC connector. (DLP 125).
8
Connect the power cable with an AC/DC power adapter to the ONT unit power
connector as shown in Figure
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
3FE 55873 AAAA TCZZA
Edition 01
ONT Product Information Guide
NTP 127 — Install an I-010G-Q or I-010G-S indoor ONT
On a flat surface, such as a desk, horizontally resting on its four plastic feet.
Figure
NTP 127-1
shows the ONT in this position.
Figure NTP 127-1: Horizontal I-010G-Q or I-010G-S indoor ONT
On a wall (I-010G-S only), by attaching the mounting bracket to the wall and
the ONT to the bracket. (DLP 122).
Power
connector
Power
switch
SC/APC
Fiber optic
connector
Warning — Be careful to maintain a bend radius of no less than 1.18
inches (3.0 cm) when connecting the fiber optic cable. A bend radius in
the cable that is too small can damage the optic fiber.
Note — Observe the following:
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 2 A.
NTP
(ETH) RJ-45
NTP 127-1
127-2.
November 2013
Ethernet
21149
and
NTP
127-2.
21148
NTP 127-3