NTP 160 — Install an I-211M-K or I-211M-L indoor ONT
Figure NTP 160-8: I-211M-L indoor ONT connections inside a Just Inside enclosure
7
Connect the ground wire (DLP 147). Optional, as required.
The ground is a range of 1/2 to 5/8 inch strip length with outer jacket aligned with
the outer surface of the enclosure.
8
Connect the Ethernet cable to the RJ-45 port (DLP 101).
9
Connect the POTS cables to the RJ-11 ports (DLP 123).
10
Connect the coaxial cable (DLP 116).
11
If used, configure the SLID (DLP 129).
12
Connect the SC/APC fiber optic cable (DLP 125).
13
Install the UPS according to manufacturer specifications (DLP 110).
NTP 160-12
November 2013
Coaxial
Ground
Pots
cable
wire
cables
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
System Status
Battery Power
Replace Battery
Auxillary Power
Silence
Alarm
Battery
Emergency Use
Ethernet
cable
POTS IDC
connector
Edition 01
ONT Product Information Guide
Power
cables
Locking
screw
Fiber optic
cables