Place the indoor ONT unit:
a
b
5
Review the connection locations as shown in Figure
6
Connect the Ethernet cables to the RJ-45 ports (DLP 101).
7
Connect the SC/APC fiber optic cable (DLP 125).
8
Install the power supply according to manufacturer specifications.
9
Connect the power cable to the power connector.
10
If used, configure the SLID (DLP 6).
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
3FE 55873 AAAA TCZZA
Edition 01
ONT Product Information Guide
On the flat surface, such as a desk, horizontally resting on its four feet as
shown in Figure
NTP
148-1; go to step 5.
Note — The I-040G-R cannot be stacked with another ONT or with
other equipment. The ONT mounting requirements are:
allow a minimum 100 mm clearance above the top cover
allow a minimum 50 mm clearance from the side vents
do not place any heat source directly above the top cover or below
the bottom cover
On a wall (DLP 122).
Figure NTP 148-1: I-040G-R indoor ONT connections
G E 1
G E 2
G E 3
G E 4
Ethernet
Reset
ports (RJ45)
button
Power
button
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
Note — Observe the following:
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 1.25 A.
NTP 148 — Install an I-040G-R indoor ONT
NTP
R E S E T
O N /O F
F
P W R
Power
Fiber optic
connector
connector
November 2013
148-1.
23678