5
Replace the ONT with a new unit:
a
b
6
Connect the Ethernet cables to the RJ-45 ports (DLP 101).
7
Connect the POTS cables to the RJ-11 ports (DLP 123).
8
Connect the coaxial cable to the F-Type connector (DLP 116).
9
If required, have approved service personnel who are trained to work with optic
fiber clean the fiber optic connection. See DLP
fiber optic handling, inspection, and cleaning.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
3FE 55873 AAAA TCZZA
Edition 01
ONT Product Information Guide
NTP 116 — Replace an G-241W-P or I-241W-T indoor ONT
Figure NTP 116-1: G-241W-P and I-241W-T ONT connections
F-Type
coaxial
connector
R F
Po w
er
O N /O
FF
Power
P O TS
connector
Power
POTS
on/off
ports
switch
(RJ-11) Ethernet
(RJ-45)
On a flat surface, such as a desk.
i
Wrap the excess optic cable for the new ONT inside the fiber storage
tray.
ii
Attach the fiber storage tray to the new ONT.
iii
Substitute the new ONT for the old ONT on a flat surface, horizontally
resting on its four feet, as shown in Figure
iv
Go to step 6.
On a wall.
i
Slide the old ONT off of the mounting screws until the ONT is free of the
wall.
ii
Slide the wall mount holes on the ONT enclosure or fiber storage tray of
the new ONT over the mounting screws until it is securely seated.
Danger — Fiber optic cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
1
P O TS
2
LA N
1
LA N
2
LA N
3
LA N
4
U S B
1
U S B
2
ports
USB
ports
134
for more information about
November 2013
23554
NTP
116-1.
NTP 116-3