B-8102-A And B-8112-A Ont Environmental Requirements; Capacity For Gem Ports And T-Conts - Alcatel-Lucent 7302 Information Manual

Intelligent services access manager
Table of Contents

Advertisement

11 — B-8102-A and B-8112-A unit data sheet
Table 11-9 B-8102-A and B-8112-A ONT environmental requirements
ONT type
Mounting method
Temperature range and humidity
Wall mounted with
Operating:
or without fiber
–40°F to 115°F (–40°C to 46°C) with solar loading
storage
–40°F to 140°F (–40°C to 60°C) without solar loading
compartment
5% to 95% relative humidity, non-condensing
Storage:
–40°F to 158°F (–40°C to 70°C)
5% to 95% relative humidity, non-condensing
Note
(1)
The maximum solar load is 753 W/m
11.7
B-8102-A and B-8112-A GEM ports and T-CONTs
This section provides the 7360 ISAM FX ONT system and service capacity
specifications.
GEM and T-CONT capacity
Table
ONT or MDU
Release
Package H ONTs
GEM ports per ONT
All
T-CONTs per ONT
All
Note
(1)
The letter x following a release number denotes either a letter of the alphabet for maintenance releases or digit from 0
to 9 for minor releases.
11.8
B-8102-A and B-8112-A power support
The following power supplies support the B-8102-A and B-8112-A. Click on the link
for more information.
"Delta DUPS-1215 UPS unit data sheet"
"Delta DMDU-4850 UPS unit data sheet"
"FlexNet FMPS-150W UPS unit data sheet"
11-10
November 2013
2
.
11-10
lists the capacity of the system for GEM ports and T-CONTs.
Table 11-10 Capacity for GEM ports and T-CONTs
(1)
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Altitude
Maximum operating altitude is 10 000
ft (3048 m) above mean sea level
(1)
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
Maximum
Notes
38
38 in SW, 38 in HW
39
39 in SW, 39 in HW
Edition 01