Ntp 128-2: I-010G-Q And I-010G-S Indoor Ont Connections (Back View) - Alcatel-Lucent 7302 Information Manual

Intelligent services access manager
Table of Contents

Advertisement

Figure NTP 128-2: I-010G-Q and I-010G-S indoor ONT connections (back view)
3
Replace the old ONT with a new unit.
4
Connect the Ethernet cable to the RJ-45 port (DLP 101).
5
If required, have approved service personnel who are trained to work with optic
fiber clean the fiber optic connection. See DLP
fiber optic handling, inspection, and cleaning.
6
Connect the fiber optic cable to the SC/APC connector on the ONT (DLP 133).
7
Connect the power cable with an AC/DC adapter to the ONT unit power connector;
as shown in Figure
8
If used, configure the SLID (DLP 129).
9
Verify the ONT LEDs and voltage status (DLP 127).
10
Activate and test the services (DLP 128).
11
If necessary, reset the ONT (DLP 126).
12
STOP. This procedure is complete.
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
3FE 55873 AAAA TCZZA
Edition 01
ONT Product Information Guide
NTP 128 — Replace an I-010G-Q or I-010G-S indoor ONT
Power
connector
Power
switch
SC/APC
Fiber optic
connector
Danger — Fiber optic cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning — Be careful to maintain a bend radius of no less than 1.18
inches (3.0 cm) when connecting the fiber optic cable. A bend radius in
the cable that is too small can damage the optic fiber.
NTP
128-2.
Note — A new SLID or the old SLID may be used with the replacement
ONT. If a new SLID is used, the new SLID must also be programmed at
the P-OLT using TL1 or a network manager. If the old SLID is used, no
changes need to be made at the P-OLT; see the Operations and
Maintenance documentation for the I-010G-Q or I-010G-S for more
details.