Ntp 122-1: I-010G-B, I-020G-M, Or I-040G-B Indoor Ont Connections - Alcatel-Lucent 7302 Information Manual

Intelligent services access manager
Table of Contents

Advertisement

Figure
ONT. The I-010G-B and I-020G-M ONT are identical to the I-040G-B ONT except for
the number of populated Ethernet ports.
4
Replace the ONT with a new unit:
a
b
c
5
Connect as many Ethernet cable to the RJ-45 ports (DLP 101) as are required.
a
b
c
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
3FE 55873 AAAA TCZZA
Edition 01
ONT Product Information Guide
NTP 122 — Replace an I-010G-B, I-020G-M, or I-040G-B indoor ONT
Figure NTP 122-1: I-010G-B, I-020G-M, or I-040G-B indoor ONT connections
Ethernet ports (RJ-45)
Power connector
Power switch
NTP 122-1
shows four available Ethernet connectors for an I-040G-B indoor
On a flat surface, such as a desk, substitute the replacement ONT for the old
ONT that is resting horizontally; go to step 5.
In a stand.
i
Unsnap the old ONT unit from the channels built into the stand. Snap
the replacement ONT into the channels built into the stand, ensuring it
is securely held.
ii
Place the new ONT with stand vertically on a flat surface; go to step 5.
On a wall.
i
Slide the old ONT upward and then away from the two mounting screws
until the ONT is free of the wall.
ii
Install the replacement ONT following the wall mounting instructions
for an I-010G-B indoor ONT (DLP 122).
For the I-010G-B indoor ONT, connect one cable.
For the I-020G-M indoor ONT, connect two cables.
For the I-040G-B indoor ONT, connect four cables.
Fiber optic connector
November 2013
NTP 122-3
20385