ReMOve akO inveRTeR - MFR18 & 25
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the back panel (See page 4-28).
2.
Remove the 8mm screw that secures the
plastic casing to the base of the washer.
Motor Control Plastic Case
Power In
and Ground
Motor Phase
Harness
Motor Speed
Control
3.
8mm Screw
4.
Interference
Filter / JP- 4
5.
4-35
Disconnect the ground wire, the incoming
power, the motor phase harness in the
center, the JP4 connector, and the wiring
connections to the interference filter. Clip
any wire ties necessary to remove the wire
connections.
nOTe: The wiring connections to the
interference filter must be reinstalled on the
same terminals they are removed from. On
this model, one has black writing and one
has blue writing. The blue is to the left. If
they are connected incorrectly, the washer
will not work.
The motor controller assembly consists
of an interference filter, power input, an
Earth/ground connection to the motor and
the motor speed control (See photo, left
column).
The motor controller assembly is replaced
as a single unit.

Advertisement

Table of Contents