Remove Cabinet - Mfr18 & 25 - Maytag MFR Series Service Manual

Hide thumbs Also See for MFR Series:
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Raise the top of the washer (See page 4-2).
2.
Disconnect the dispenser to tub hose by
loosening the hose clamp and pulling the
hose off the bottom of the dispenser.
Dispenser to Tub
Hose Clamp
3.
Clip the wire ties that secure the hose from
the air dome to the water level control on
the control board. Pull the hose from the
control board.
Water Level
Control
ReMOve CaBineT - MFR18 & 25
4.
Unplug door lock wire harness at DL1 by
squeezing the locking tab and pulling it off
the control board. Cut wire ties that secure
door lock cable to the front panel.
Door Lock Wire
Harness At DL1
5.
Remove the back panel (See page 4-28).
6.
Remove the temperature sensor at the back
of the tub (See page 4-42).
7.
Clip the wire ties that secure the motor wire
harness to the back of the tub.
8.
Disconnect the vent tube connected to the
overflow.
Vent Tube
Clamp
9.
Remove the lower service panel
(See page 4-12).
5-4
Wire Ties For Motor
Wire Harness