Remove Door Lock Solenoid; Remove Door Unlock Solenoid - Maytag MFR Series Service Manual

Hide thumbs Also See for MFR Series:
Table of Contents

Advertisement

ReMOve DOOR
lOCk SOlenOiD
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove door lock assembly
(See page 4-23).
2.
Remove the bimetal (See page 8-23).
3.
Remove two star head screws and remove
the door lock solenoid.
Two Star
Head Screw
8-25
ReMOve DOOR
unlOCk SOlenOiD
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove door lock assembly
(See page 4-23).
2.
Remove two star head screws and remove
the door unlock solenoid.
Two Star
Head Screws

Advertisement

Table of Contents
loading