Remove And Reinstall Belts - Mfr25 - Maytag MFR Series Service Manual

Hide thumbs Also See for MFR Series:
Table of Contents

Advertisement

ReMOve anD ReinSTall BelTS - MFR25

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the back panel (See page 4-28).
2.
Remove the large belt by rolling it off the
basket pulley.
3.
Remove the small belt the same way.
4.
To reinstall the small belt, loosen the motor
so that it can move up slightly to make
reinstallation of the small belt easier.
5.
Reinstall the small belt on the largest
diameter of the idler pulley and around the
motor shaft.
6.
Reattach the two springs.
Small Belt
Motor
Shaft
7.
Reinstall the large belt on the basket pulley
and around the smaller front diameter
portion of the idler pulley.
8.
Push down on the motor to adjust the
tension on the belts.
9.
Tighten the bolt on the motor.
Springs
Motor
Tension
Adjustment
4-29
Large Belt

Advertisement