ReMOve COnTaCTOR

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Raise the top of the washer (See page 4-2).
2.
Push down on the top of the contactor
and lift the bottom out to release it from its
mounting bracket.
3.
Disconnect the wire connectors.
Contactor
ReMOve TRanSFORMeR
MFR18 & 25
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Raise the top of the washer (See page 4-2).
2.
Remove the four flat blade screws from
the back of the washer that secure the
transformer mounting bracket.
4 Flat Blade
Screws
3.
Support the transformer and bracket before
removing the final screw to keep it from
falling inside the washer.
4.
Remove the transformer and bracket.
5.
Disconnect the wire connectors.
4-27