Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the lower service panel
(See page 4-12).
2.
Remove the drain valve wire connector
cover.
3.
Disconnect three wire connectors under the
cover.

ReMOve DRain valve

3 Wire
Connectors
4-40
4.
Remove the air dome hose and fill hose
from the supply box by loosening the
clamps and pulling the hoses off.
5.
Loosen the hose clamp that secures the
inlet hose on the top.
Air Dome
Hose Clamp
6.
Reach around to the back of the drain valve
and loosen the hose clamp that secures the
outlet hose.
Inlet Hose
Clamp
Fill Hose
Clamp
Outlet Hose
Clamp