Remove Blocking Bar; Remove Door Closed Switch - Maytag MFR Series Service Manual

Hide thumbs Also See for MFR Series:
Table of Contents

Advertisement

ReMOve BlOCkinG BaR

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the bimetal (See page 8-23).
2.
Guide the top end of the blocking bar over
the tip of the bimetal plunger to remove the
blocking bar.
ReMOve DOOR
ClOSeD SWiTCH
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove door lock assembly
(See page 4-23).
2.
Disconnect the wires to the door closed
switch.
3.
Remove 2 star head screws that mount
the switch to the bottom of the door lock
assembly.
4.
Remove the actuator arm with a small
screwdriver using a twisting motion.
Actuator arm may be needed for
replacement switch.
Actuator
Arm
8-24
Two Star
Head Screws

Advertisement