Inlet Valve-Stem Assembly Parts - Maytag MFR Series Service Manual

Hide thumbs Also See for MFR Series:
Table of Contents

Advertisement

inleT valve-STeM aSSeMBly paRTS

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Raise the top of the washer (See page 4-2).
2.
Disconnect the coil connections.
3.
Use a small screw driver to pry the coil off
the stem assembly.
4.
Use a pair of needle nose pliers as a
wrench to turn the stem assembly counter-
clockwise to remove it.
Coil
Stem
5.
The stem assembly consists of a
diaphragm, a plunger with a rubber tip and a
return spring.
Diaphragm
6.
Inside the valve, the water comes in on
one side and exits out the middle of the
inlet valve. If the metal sealing surfaces are
damaged, the complete valve assembly
needs to be replaced.
Water In
7.
To reassemble the stem assembly, reinstall
the return spring.
8.
Install the plunger with the rubber tip facing
up.
9.
Push the diaphragm on until it catches so it
does not fall out.
nOTe: Kit is available for repairing
Elbi-Bitron® inlet valves;
Diaphragm part #23003442.
7-2
Rubber Tip
Plunger
Spring
Water Out

Advertisement

Table of Contents
loading

Table of Contents