Mitsubishi MELSEC Q Series Programming Manual page 1161

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Number
Name
OFF : No. 1 CPU reset
No. 1 CPU reset
flag
ON : No. 1 CPU
SM240
No. 1 CPU reset
Reset status
flag
OFF : No. 2 CPU reset
No. 2 CPU reset
SM241
flag
ON : No. 2 CPU
OFF : No. 3 CPU reset
No. 3 CPU reset
SM242
flag
ON : No. 3 CPU
OFF : No. 4 CPU reset
No. 4 CPU reset
SM243
flag
ON : No. 4 CPU
OFF : No. 1 CPU normal
No. 1 CPU error
SM244
ON : No. 1 CPU during
flag
OFF : No. 2 CPU normal
No. 2 CPU error
SM245
ON : No. 2 CPU during
flag
OFF : No. 3 CPU normal
No. 3 CPU error
SM246
ON : No. 3 CPU during
flag
OFF : No. 4 CPU normal
No. 4 CPU error
SM247
ON : No. 4 CPU during
flag
Max. loaded I/O
OFF : Ignored
SM250
read
ON : Read
OFF : Refresh arrival
All stations
SM254
refresh command
ON : Refresh all
Meaning
• Turns off when CPU No.1 is reset.
• Turns on while CPU No.1 is being reset
cancel
(including the case where the CPU module
is removed from the base unit). The other
resetting
CPUs are also put in reset status.
• This relay is always off. (reset status)
• Turns off when CPU No.2 is reset.
• Turns on while CPU No.2 is being reset
cancel
(including the case where the CPU module
is removed from the base unit). "MULTI
resetting
CPU DOWN" (error code: 7000) is
detected on the other CPUs.
• Turns off when CPU No.3 is reset.
• Turns on while CPU No.3 is being reset
cancel
(including the case where the CPU module
is removed from the base unit). "MULTI
resetting
CPU DOWN" (error code: 7000) is
detected on the other CPUs.
• Turns off when CPU No.4 is reset.
• Turns on while CPU No.4 is being reset
cancel
(including the case where the CPU module
is removed from the base unit). "MULTI
resetting
CPU DOWN" (error code: 7000) is
detected on the other CPUs.
• This relay is off when CPU No.1 is normal
(including the case where a continuation
error has occurred).
stop error
• This relay is on when CPU No.1 has a stop
error.
• This relay is on when CPU No.2 is normal
(including the case where a continuation
error has occurred).
stop error
• This relay is on when CPU No.2 has a stop
error.
• This relay is off when CPU No.3 is normal
(including the case where a continuation
error has occurred).
stop error
• This relay is on when CPU No.3 has a stop
error.
• This relay is off when CPU No.4 is normal
(including the case where a continuation
error has occurred).
stop error
• This relay is on when CPU No.4 has a stop
error.
When this relay turns on from off, the largest
I/O number among those of the mounted
modules is read into SD250.
• Effective for the batch refresh (also
effective for the low speed cyclic)
• Designate whether to receive arrival
stations only or to receive all slave stations
in the MELSECNET/H.
station
• Effective for the batch refresh (also
stations
effective for the low speed cyclic)
• Designate whether to receive arrival
stations only or to receive all slave stations
in the CC-Link IE controller network .
Explanation
(When Set)
S (Status
change)
Corres-
ponding
Set by
Corresponding
ACPU
CPU
M9
Q00/Q01
Qn(H)
QnPH
QnU
LCPU
Q00/Q01
Qn(H)
QnPH
QnU
Qn(H)
QnPH
QnU
Q00/Q01
Qn(H)
QnPH
QnU
New
LCPU
Q00/Q01
Qn(H)
QnPH
QnU
Qn(H)
QnPH
QnU
Qn(H)
U
QnPH
QnPRH
App-153
8
*1
*1
8
*7
8
8
*1
*1
A
*7
6
*1
7
*5
*1
8
*1
*7
*1
*1
*7
*1
*5