Mitsubishi MELSEC Q Series Programming Manual page 1221

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Number
Name
Meaning
SD207
Priorities 1 to 4
SD208
Priorities 5 to 8
LED display
priority
ranking
Priorities 9 to
SD209
12
Explanation
• The priority of the LED indication in the case of an error is set
by a cause number. (For the Basic model QCPU, only the
annunciator (cause number 7) is available.)
• For the Universal model QCPU and LCPU, specify whether to
enable or disable LED indication of the error that has priority
when an error occurs.
• The setting areas for priorities are as follows:
b15
b12
b11
b8
b7
to
to
SD207
Priority 4
Priority 3
Priority 2
SD208
Priority 8
Priority 7
Priority 6
SD209
Priority 12
Priority 11
Priority 10
(Priority 11 is valid when Redundant CPU is used.)
(Priority 12 is valid when LCPU is used.)
[Default value]
SD207 = 4321
(0000
for Basic model QCPU)
H
H
SD208 = 8765
(0700
for Basic model QCPU) (0765
H
H
Redundant CPU)
SD209 = 00A9
(0000
for Basic model QCPU) (0B09
H
H
Redundant CPU, CBA9
for LCPU)
H
• No indication if "0" is stored.
• For the Basic model QCPU, the ERR. LED lights up upon
turn-on of the annunciator, if "7" is stored in any of Priorities 1
to 11.
• For the Basic model QCPU, the ERR. LED does not light up
upon turn-on of the annumciator, if "7" is not stored in any of
Priorities 1 to 11.
However, even if "7" is stored, the error, which makes CPU
module operation stop (including the error that is specified
with a parameter), will be indicated with the LED without
condition.
Set by
(When Set)
b4
b3
b0
to
to
Priority 1
Priority 5
Priority 9
U
for
H
for
H
Corres-
Corres-
ponding
ponding
ACPU
CPU
D9
D9038
D9039
format
change
Q00J/ Q00/
* 1
Q01
Qn(H)
QnPH
QnPRH
QnU
LCPU
New
App-213
8
8
8
8
A
6
7
8