Mitsubishi MELSEC Q Series Programming Manual page 1275

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Number
Name
SD1868
Axis 2 movement
Movement amount
amount after
after near-point dog
near-point dog
SD1869
ON
ON
Axis 2 Data No. of
Data No. of
SD1870
positioning being
positioning being
executed
executed
SD1880
CH1 current value
CH1 current value
SD1881
CH1 status
SD1882
CH1 status monitor
monitor
Meaning
• This register stores "0" when machine OPR control is
started.
• After machine OPR control is started, this register
stores a travel distance from the point where the
near-point watchdog signal turns on (The point is set
to "0".) to the point where machine OPR control is
completed.*1
• When an OPR method is set to Stopper 3, this
register always stores "0".
*1 Range: 0 to 2147483647 pulses
• This register stores the data No. of positioning being
executed.
(A storage value will be held until the next control
starts.)
• "0" is stored when JOG operation or machine OPR
control is started.
• "1" is stored when high-speed OPR control is started.
• "1" is stored when positioning control is started by
the IPDSTRT1 or IPDSTRT2 instruction.
• If an error occurs at the start of positioning control,
the previous value will be held.
• This register stores the current counter value of CH1
at END processing.
• When the ICCNTRD1 instruction is executed, this
register is updated by the current value at that
moment.
The current value is updated at END processing and
by the ICCNTRD1 instruction only when Normal
Mode is set for Operation Mode Setting (high-speed
counter function parameter). The range of a value
that can be read is from -2147483648 to
2147483647.
This register stores each status of CH1.
b15
to
b8
b7
b6
b5
b4
0/1
0/1
0/1 0/1 0/1 0/1 0/1 0/1
0
Explanation
b3
b2 b1 b0
Addition/subtraction
0: Addition
1: Subtraction
Underflow detection flag
0: Not detected
1: Detected
Overflow detection flag
0: Not detected
1: Detected
Sampling flag
0: Not operating
1: Operating
Frequency measurement flag
0: Not operating
1: Operating
Rotation speed
measurement flag
0: Not operating
1: Operating
Pulse measurement flag
0: Not operating
1: Operating
PWM output flag
0: Not operating
1: Operating
Fixed to 0.
Corres-
Corres-
ponding
Set by
ponding
ACPU
(When Set)
CPU
D9
S
(Every END
processing)
S
(Every END
processing/
Instruction
execution)
New
LCPU
S
(Every END
processing)
App-267
8
8
8
8
A
6
7
8