Mitsubishi MELSEC Q Series Programming Manual page 1163

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Number
Name
OFF : Not connected
SM310
RS-232 adapter
ON :Connected
Communication
reserved time
OFF : Without delay
SM315
delay enable/
ON : With delay
disable flag
Automatic CC-
OFF : Not activated
SM319
Link start
ON : Activated
OFF : SFC program
Presence/
SM320
absence of SFC
ON : SFC program
program
OFF : SFC program not
Start/stop SFC
SM321
program
ON : SFC program
SFC program
OFF : Initial start
SM322
start status
ON : Resume start
Presence/
OFF : Continuous
absence of
SM323
continuous
transition for
ON : Continuous
entire block
OFF : When transition is
Continuous
SM324
transition
ON : When no
prevention flag
Meaning
This relay stores information on whether an
RS-232 adapter is connected or not.
Connection of an RS-232 adapter is checked
at the time of initialization, and if it is
connected, this relay turns on. The on/off
status set during initialization is held until the
power is turned off and on again or the
system is reset.
• This flag is enabled when the time reserved
for communication processing is set in
SD315.
• Turns ON to delay the END processing by
the time set in SD315 in order to perform
communication processing.
(The scan time increases by the period set
in SD315.)
• Turns OFF to perform the END processing
without a delay of the time set in SD315
when there is no communication
processing. (Defaults to OFF)
• This relay indicates whether the CC-Link
module is started and all the data are
refreshed by the automatic CC-Link start
function.
• This relay is on when all the data are
refreshed by the automatic CC-Link start
function.
• Then the automatic CC-Link start function
is not activated, or when the refresh device
range is insufficient, this relay is turned off.
(If the refresh device range set for the
automatic CC-Link start function is
insufficient, all of the refresh is stopped.)
• This relay is on if an SFC program is
absent
registered.
• This relay turns off if no SFC program is
present
registered.
• The same value as in SM320 is set as the
initial value.
(This relay turns on when an SFC program
executed (stop)
is registered.)
• Turning off this relay stops SFC program
executed (start)
execution.
• Turning on this relay restarts SFC program
execution.
In the SFC setting of the PLC Parameter
dialog box, Initial start is set for the SFC
program start mode.
• At initial start: OFF
• At continued start: ON
Set the presence/absence of continuous
transition not
transition for the block where "Continuous
effective
transition bit" of the SFC data device has not
been set.
transition effective
• This relay is off while the module is in the
continuous transition mode or during
continuous transition, and is on when
executed
continuous transition is not executed.
• This relay is always on while the CPU
transition
module is operating not in the continuous
transition mode.
Explanation
(When Set)
S (Initial)
S (Initial
processing and
status change)
S (Initial)
S (Initial)/U
S (Instruction
execution)
S (Status
change)
Corres-
ponding
Set by
Corresponding
ACPU
CPU
M9
LCPU
U
Q00J/Q00/Q01
New
LCPU
M9100
M9101
format
change
Q00J/Q00/Q01
Qn(H)
QnPH
QnPRH
M9102
QnU
format
LCPU
change
U
M9103
M9104
Q00J/Q00/Q01
Qn(H)
New
QnPH
QnPRH
QnU
App-155
8
8
8
8
A
6
7
8
*1
*1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: