Category
Instruction
COM
CCOM
FIFW
Application
FIFR
instruction
FPOP
FINS
FDEL
FROM n1 n2
n3
D
DFRO n1 n2
n3
D
TO n1 n2
n3
S
DTO n1 n2
n3
S
LEDR
BINDA
S
D
DBINDA
S
D
Condition (Device)
When selecting I/O refresh only
When selecting CC-Link refresh
only (Master station side)
When selecting CC-Link refresh
only (Local station side)
When selecting MELSECNET/H
refresh only (Control station side)
When selecting MELSECNET/H
refresh only (Normal station side)
When selecting intelli auto
refresh only
When selecting I/O outside the
group only (Input only)
When selecting I/O outside the
group only (Output only)
When selecting I/O outside the
group only (Both I/O)
When selecting refresh of multi-
ple CPU high speed transmission
area only
When selecting communication
with peripheral device
Number of data points = 0
Number of data points = 96
Number of data points = 0
Number of data points = 96
Number of data points = 0
Number of data points = 96
Number of data points = 0
Number of data points = 96
Number of data points = 0
Number of data points = 96
n3 = 1
n3 = 1000
n3 = 1
n3 = 500
n3 = 1
n3 = 1000
n3 = 1
n3 = 500
No display
no display
LED instruction execution
no
display
= 1
S
= -32768
S
= 1
S
= -2147483648
S
Processing Time (µs)
Q00UJCPU
Q00UCPU
Min.
Max.
Min.
Max.
18.100
89.100
18.100
89.100
33.300
132.000
33.300
132.000
33.300
33.300
132.000
132.000
78.600
78.600
231.000
231.000
78.600
78.600
231.000
231.000
18.100
89.000
18.100
89.000
15.700
71.600
15.700
71.600
40.200
40.200
152.000
152.000
45.800
45.800
153.000
153.000
––
––
––
––
18.200
89.000
18.200
89.000
6.100
14.200
6.100
14.200
6.100
14.200
6.100
14.200
7.500
15.600
7.500
15.600
37.000
45.000
37.000
45.000
7.600
15.600
7.600
15.600
7.600
15.600
7.600
15.600
6.900
15.000
6.900
15.000
36.600
44.700
36.600
44.700
8.000
16.100
8.000
16.100
37.300
45.500
37.300
45.500
17.400
74.700
17.400
74.700
406.000 498.500 406.000 498.500 406.000 498.500 402.600 495.100
19.600
85.600
19.600
85.600
406.000 498.500 406.000 498.500 406.000 498.500 402.600 495.100
16.400
69.600
16.400
69.600
381.300 471.200 381.300 471.200 381.300 471.200 375.900 464.300
18.600
85.100
18.600
85.100
381.300 471.200 381.300 471.200 381.300 471.200 375.900 464.300
1.500
7.100
1.500
7.100
38.900
38.900
109.000
109.000
5.600
13.900
5.600
13.900
7.800
16.200
7.800
16.200
6.200
14.500
6.200
14.500
11.000
19.200
11.000
19.200
Q01UCPU
Q02UCPU
Min.
Max.
Min.
Max.
18.100
89.100
12.800
79.000
33.300
132.000
24.900
119.000
33.300
24.900
132.000
119.000
78.600
54.000
231.000
212.000
78.600
54.000
231.000
212.000
18.100
89.000
12.800
79.000
15.700
71.600
8.600
76.500
40.200
26.300
152.000
135.000
45.800
26.100
153.000
135.000
––
––
––
––
18.200
89.000
7.250
54.300
6.100
14.200
3.700
10.100
6.100
14.200
3.800
5.200
7.500
15.600
4.400
5.800
37.000
45.000
33.500
35.200
7.600
15.600
4.400
10.800
7.600
15.600
4.400
10.800
6.900
15.000
5.000
10.700
36.600
44.700
4.400
10.900
8.000
16.100
4.900
11.300
37.300
45.500
34.200
35.900
17.400
74.700
12.100
71.300
19.600
85.600
14.600
81.800
16.400
69.600
11.700
63.400
18.600
85.100
14.200
78.500
1.500
7.100
5.100
5.100
38.900
35.700
89.200
109.000
5.600
13.900
4.900
6.500
7.800
16.200
7.200
8.700
6.200
14.500
5.700
7.100
11.000
19.200
10.400
12.200
App-75
8
8
8
8
A
6
7
8

Hide quick links: