Mitsubishi MELSEC Q Series Programming Manual page 1216

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Number
Name
Battery life-
Battery life-
SD119
prolonging
prolonging
factor
factor
SD130
SD131
Bit pattern in
SD132
units of 16
points,
SD133
indicating the
SD134
modules whose
Fuse blown
fuses have
SD135
module
blown
SD136
0: No blown
1: Blown fuse
SD137
SD150
SD151
Bit pattern, in
SD152
units of 16
points,
SD153
indicating the
SD154
I/O module
modules with
SD155
verify error
verify errors.
0: No I/O verify
SD156
1: I/O verify
SD157
*1
The module whose first 5 digits of serial No. is "07032" or later.
*2
The module whose first 5 digits of serial No. is "10042" or later.
*3
This applies to Universal model QCPUs except for the Built-in Ethernet port QCPU.
*4
The module whose first 5 digits of serial No. is "10102" or later.
App-208
Meaning
This register stores a value indicating a cause that has the
battery life-prolonging function enabled. While this register is
other than "0", the battery life-prolonging function is enabled.
b15
to
Fixed to 0
• This register stores the number of a fuse-blown output
module (in units of 16 points) in the following bit pattern.
(When module numbers have been set by the parameter, the
parameter-set numbers are stored.)
b15 b14 b13 b12 b11b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
0
0
0
SD130
1
SD131
0
0
(Y1F0)
0
0
0
SD137
fuse
present
• Not cleared even if the blown fuse is replaced with a new
one. The storage value is cleared by clearing the error.
• If the status of the I/O module changes from that obtained at
power-on, the module No. (unit: 16 points) is stored in the
following bit pattern. (When I/O module numbers have been
set by the parameter, the parameter-set numbers are stored.)
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
0
0
0
SD150
0
0
0
SD151
1
errors
0
0
SD157
X Y
( )
7E0
error present
• Not cleared even if the blown fuse is replaced with a new
one. The storage value is cleared by clearing the error.
Explanation
b2 b1 b0
b0: CPU switch setting
b1: Backup in execution by
latch data backup function
(to standard ROM)
1
1
0
0
0
0
0
0
0
(YC0)
(Y80)
1
0
0
0
0
0
0
0
0
(Y1A0)
1
0
0
0
0
0
0
0
0
(Y7B0)
Indicates fuse blow.
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
X Y
(
)
190
0
0
0
0
0
0
0
0
0
Indicates an I/O module verify error.
Set by
(When Set)
S
0:No factor
1:Factor
(Status
change)
0
0
0
0
0
0
0
0
1
0
0
0
(Y730)
S
(Error)
1
0
0
0
X Y
( )
0
0
0
0
0
0
0
0
0
Corres-
Corres-
ponding
ponding
ACPU
CPU
D9
QnU
LCPU
New
Q00J/Q00/
Q01