Mitsubishi MELSEC Q Series Programming Manual page 1064

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

(b) When using Q03UD(E)HCPU, Q04UD(E)HCPU, Q06UD(E)HCPU,
Category
Instruction
LD
LDI
AND
ANI
OR
ORI
LDP
LDF
ANDP
ANDF
ORP
Sequence
ORF
instruction
LDPI
LDFI
ANDPI
ANDFI
ORPI
ORFI
OUT
SET
RST
App-56
Q10UD(E)HCPU,Q13UD(E)HCPU, Q20UD(E)HCPU, Q26UD(E)HCPU
Condition (Device)
When executed
When executed
When executed
When not changed
When changed
When not executed
Processing Time (µs)
Q03UD(E)CPU
Q04/Q06UD(E)HCPU
Min.
Max.
Min.
0.020
0.0095
0.060
0.0285
0.080
0.038
0.020
0.0095
0.020
0.0095
Q10/Q13/Q20/
Q26UD(E)HCPU
Max.
Min.
0.0095
0.0285
0.038
0.0095
0.0095
Max.

Hide quick links: