Mitsubishi MELSEC Q Series Programming Manual page 1181

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Special
Special
ACPU
Relay after
Relay for
Special
Relay
Conversion
Modification
M9047
SM1047
SM801
M9049
SM1049
SM701
M9051
SM1051
×
M9052
SM1052
×
M9056
SM1056
×
M9057
SM1057
×
M9058
SM1058
×
M9059
SM1059
×
M9060
SM1060
×
M9061
SM1061
×
M9070
SM1070
×
M9084
SM1084
×
M9091
SM1091
×
Name
Meaning
OFF : Sampling trace
Sampling trace
suspended
preparations
ON : Sampling trace
started
OFF : Output until
Switching the
NULL code
number of
encountered
output
ON : 16 characters
characters
output
CHG instruction
OFF : Enabled
execution
ON : Disable
disable
OFF : 7SEG segment
SEG instruction
display
switch
ON : I/O partial
refresh
OFF : Other than
when P, I set
Main side P, I
being requested
set request
ON : P, I set being
requested
OFF : Other than
when P, I set
Sub side P, I set
being requested
request
ON : P, I set being
requested
Main side P, I
Momentarily ON at P, I
set completion
set completion
Sub program P, I
Momentarily ON at P, I
set completion
set completion
OFF : Other than
when P, I set
Sub program 2
being requested
P, I set request
ON : P, I set being
requested
OFF : Other than
when P, I set
Sub program 3
being requested
P, I set request
ON : P, I set being
requested
OFF : Read time not
A8UPU/
shortened
A8PUJrequired
ON : Read time
*3
search time
shortened
OFF : Error check
Error check
executed
ON : No error check
Operation error
OFF : No error
details flag
ON : Error
Details
Sampling trace is not executed unless SM1047
is turned ON. Sampling trace is cancelled when
SM1047 turns off.
• When SM1049 is off, characters up to NULL
(00
) code are output.
H
• When SM1049 is ON, ASCII codes of 16
characters are output.
• Switched ON to disable the CHG instruction.
• Turn this on when requesting program
transfer. It is automatically turned off upon
completion of the transfer.
When SM1052 is on, the SEG instruction is
used as an I/O part refresh instruction. When
SM1052 is off, the SEG instruction is used as a
7-SEG display instruction.
While a program is running, upon completion of
transfer of another program (for example, a
subprogram when the main program is running),
a P and I set request is turned on. This relay
automatically turns off upon completion of P and
I setting.
This relay turns on for a moment upon
completion of P and I setting, and immediately
turns off.
While a program is running, upon completion of
transfer of another program (for example, a
subprogram when the main program is running),
a P and I set request is turned on. This relay
automatically turns off upon completion of P and
I setting.
When this is turned on, the search time in the
A8UPU/A8PUJ can be shortened. (In this case,
the scan time is extended by 10%.)
This relay sets whether or not to check the
following errors at the time of the END
instruction processing (for setting of the END
instruction processing time).
• Check for fuse blown.
• Check of battery
• Collation check of I/O module
• This relay turns on when the detail factor of
the operation error is stored into SD1091.
• This relay remains on even after the condition
returns to normal.
Corres-ponding
CPU
8
8
Qn(H)
QnPH
8
8
A
6
7
8
-
App-173

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec l series

Table of Contents