Mitsubishi MELSEC Q Series Programming Manual page 1199

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Number
Name
CH2 counter
OFF : Not detected
SM1904
value coincidence
ON : Detected
(No.2)
OFF : Coincidence
CH2 counter
SM1905
value smaller
ON : Smaller than
(No.2)
CH2 external
OFF : Not detected
SM1906
preset (phase Z)
ON : Detected
request detection
OFF : No error
SM1907
CH2 Error
ON : Error
OFF : No warning
SM1908
CH2 warning
ON : Warning
CH2 coincidence
Resets CH2 counter
SM1910
signal No.1 reset
value coincidence No.1.
command
CH2 coincidence
Resets CH2 counter
SM1911
signal No.2 reset
value coincidence No.2.
command
Controls outputs from
CH2 coincidence
CH2 coincidence output
SM1912
output enable
No.1 and No.2
command
terminals.
CH2 preset
Presets the counter
SM1913
command
value.
CH2 count down
SM1914
Counts down pulses.
command
Meaning
• This relay turns on when "current value of
CH2 = coincidence output No.2 point
setting value" is met.
• This relay is turned off by turning on CH2
coincidence signal No.2 reset command.
• This relay turns on when "current value of
point (No.2) or
CH2 < coincidence output No.2 point
greater
setting value" is met.
• This relay turns off when "current value of
CH2 ≥ coincidence output No.2 point
coincidence point
(No.2)
setting value" is met.
• This relay turns on when a preset request
by phase Z (preset) terminal of CH2 is
detected.
• This relay is turned off by turning on CH2
external preset (phase Z) request detection
clear command.
• This relay turns on if the CH2 error occurs.
• This relay turns off when an error cause is
removed and CH2 error reset command is
turned on.
• This relay turns on if a warning occurs in
CH2.
• This relay turns off when a warning cause
is removed and CH2 error reset command
is turned on.
• This relay is turned on to reset CH2
counter value coincidence No.1.
• The command is valid while this relay is on.
• The on time must be held for at least 2ms.
• This relay is turned on to reset CH2
counter value coincidence No.2.
• The command is valid while this relay is on.
• The on time must be held for at least 2ms.
• This relay is turned on to perform
coincidence output from CH2 coincidence
output No.1 and CH2 coincidence output
No.2 terminals.
• The command is valid while this relay is on.
• This relay is turned on to preset the counter
value.
• The command is valid at the rise of this
relay (off → on).
• The on and off time must be held for at
least 2ms.
• This relay is turned on to count down
pulses.
• The command is valid while the Pulse input
mode is either 1-phase multiple of n or 1-
phase multiple of n (A phase only).
• The command is valid while this relay is on.
Set by
Explanation
(When Set)
change/
Every END
processing)
(Every END
processing)
Corres-
ponding
Corresponding
ACPU
CPU
M9
S
(Status
S
New
LCPU
U
App-191
8
8
8
8
A
6
7
8