Mitsubishi MELSEC Q Series Programming Manual page 1227

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Number
Name
Meaning
16 bit
Device
modification
assignment
SD305
Number of
(Index
points
register)
assigned for Z
SD306
Device
Number of
assignment
points
(Same as
assigned for
SD307
parameter
ZR (for
contents)
extension)
SD308
Device
Number of
assignment
points
(assignment
assigned for D
SD309
including the
(for inside + for
number of
extension)
points set to
SD310
Number of
the extended
points
data register
assigned for W
(D) and
SD311
(for inside + for
extended link
extension)
register (W))
Time reserved
Time reserved
for
for
SD315
communicatio
communication
n processing
processing
No. of modules
SD340
installed
SD341
I/O No.
Network
SD342
No.
SD343
Ethernet
Group No.
information
SD344
Station No
SD345
to
Empty
SD346
SD347
Empty
SD348
Information
to
from 2nd
SD354
module
SD355
Information
Ethernet
to
from 3rd
information
SD361
module
SD362
Information
to
from
SD368
4th module
Explanation
Stores the number of points of index register (Z) used for the
16-bit modification area. (Depending on the index modification
setting for ZR in the parameter setting.)
The number of points for ZR is stored (except the number of
points of extended data register (D) and extended link register
(W)). The number of points assigned to ZR is stored into this
register only when 1k point or more is set for the extended data
register (D) or extended link register (W).
The total points of the data register (D) in the internal device
memory area and the extended data register (D) are stored as a
32-bit binary value.
The total points of the link register (W) in the internal device
memory area and the extended link register (W) are stored as a
32-bit binary value.
• This register specifies the amount of processing time for
communication with a programming tool or another module.
• The greater the value specified is, the shorter the response
time for communication with another (such as a programming
tool or serial communication module) is. However, scan time
will increase by the specified time.
• Setting range: 1 to 100ms A setting outside the above range
is regarded as no setting.
Indicates the number of mounted Ethernet module.
Indicates I/O No. of mounted Ethernet module
Indicates network No. of mounted Ethernet module
Indicates group No. of the mounted Ethernet module.
Indicates station No. of mounted Ethernet module
Empty (The IP address of the 1st Ethernet module is stored in
the buffer memory.)
Empty (An error code of the 1st Ethernet module is read with
the ERRRD instruction.)
Data configuration is the same as that of the 1st module
(SD341 to SD347).
Data configuration is the same as that of the 1st module
(SD341 to SD347).
Data configuration is the same as that of the 1st module
(SD341 to SD347).
Corres-
Corres-
ponding
Set by
ponding
ACPU
(When Set)
CPU
D9
QnU
LCPU
S
(Initial)
QnU
LCPU
Q00J/Q00/
Q01
U
Qn(H)
QnPH
New
QnPRH
QCPU
Qn(H)
S
QnPH
(Initial)
QnPRH
QnU
Qn(H)
QnPH
QnPRH
QnU
App-219
8
8
8
8
*7
A
6
7
8
*2
*3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec l series