Mitsubishi MELSEC Q Series Programming Manual page 1158

Common instruction 1/2
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Number
Name
AC/DC DOWN
SM53
detection
AC/DC DOWN
SM53
detection
SM56
Operation error
Blown fuse
SM60
detection
I/O module verify
SM61
error
Annunciator
SM62
detection
SM80
CHK detection
SM84
Error clear
SM90
SM91
SM92
SM93
Startup of
monitoring timer
SM94
for step transition
(Enabled only
SM95
when SFC
program exists)
SM96
SM97
SM98
SM99
App-150
Meaning
This relay turns on if a momentary power
failure within 20ms occurs during use of an AC
power supply module. This relay is reset when
OFF : AC/DC DOWN
the CPU module is powered off and then on.
not detected
ON : AC/DC DOWN
This relay turns on if a momentary power
detected
failure within 10ms occurs during use of an AC
power supply module. This relay is reset when
the CPU module is powered off and then on.
OFF : AC/DC DOWN
This relay turns on if a momentary power
not detected
failure within 10ms occurs during use of a DC
ON : AC/DC DOWN
power supply module. This relay is reset when
detected
the CPU module is powered off and then on.
• This relay turns on if an operation error
OFF : Normal
occurs.
ON : Operation error
• This relay remains on even after the system
returns to normal.
• Turns on if there is at least one output
module whose fuse has blown.
OFF : Normal
• This relay remains on even after the system
ON : Module with
returns to normal.
blown fuse
• Output modules on remote I/O stations are
also checked.
• This relay turns on if the status of the I/O
module differs from that registered at power-
on.
OFF : Normal
• This relay remains on even after the system
ON : Error
returns to normal.
• I/O modules on remote I/O stations are also
checked.
OFF : Not detected
This relay turns on if at least one annunciator
ON : Detected
(F) turns on.
• This relay turns on if an error is detected by
OFF : Not detected
the CHK instruction.
ON : Detected
• This relay remains on even after the system
returns to normal.
This relay is turned on to clear an error set to
OFF→ON: Error clear
SD84 and SD85.
Corresponds to
SD90
Corresponds to
SD91
Corresponds to
SD92
Corresponds to
SD93
OFF : Not started
Corresponds to
(monitoring timer
SD94
reset)
ON : Started
Corresponds to
(monitoring timer
SD95
started)
Corresponds to
SD96
Corresponds to
SD97
Corresponds to
SD98
Corresponds to
SD99
Explanation
• Goes ON when
measurement of step
transition monitoring
timer is commenced.
• Resets step transition
monitoring timer when
it goes OFF.
Corres-
ponding
Set by
Corresponding
ACPU
(When Set)
M9
M9005
M9005
M9011
S (Error)
M9000
M9002
M9009
S (Instruction
execution)
New
M9108
M9109
M9110
M9111
U
M9112
M9113
M9114
New
CPU
QCPU
LCPU
QCPU
LCPU
QCPU
QCPU
LCPU
Qn(H)
QnPH
QnPRH
LCPU
Qn(H)
QnPH
QnPRH