Visual Inspection System Protocol
Sequence
Communications
No.
sequence name
471 (01D7)
Camera designation
and positioning (F350)
472 (01D8)
Scene switching and
positioning (F350)
473 (01D9)
Inspection execution
and character inspec-
tion (F350)
474 (01DA)
Character string inspec-
tion and character
inspection (F350)
480 (01E0)
Camera change
(decrease by 1) (F200/
300)
481 (01E1)
Camera change
(increase by 1) (F200/
300)
482 (01E2)
Binary level modification
(F200/300)
483 (01E3)
Reset (F200/300)
490 (01EA)
Scene switch (decrease
by 1)
491 (01EB)
Scene switch (increase
by 1)
492 (01EC)
Scene switch (arbitrary) Switches to a designated scene No.
493 (01ED)
Measurement, inspec-
tion termination
494 (01EE)
General-purpose com-
mand (send)
495 (01EF)
General-purpose com-
mand send/(receive)
Note 1. The hexadecimal equivalents of sequences numbers are given in parentheses.
2. Ladder Interface Settings
YES: User settings are required for the 3rd and 4th operands of PMCR(260).
NO:
Send word allocation:
Receive word allocation:
3. Sequences No. 452 and No. 462 (Continuous Measurement Execution with Interrupt) are not sup-
ported by the CS1W-SCU@@(-V1) and CJ1W-SCU@@(-V1) Serial Communications Units. A protocol
syntax error will occur if an attempt is made to execute either sequence with a Serial Communications
Unit.
Do not set an EM bank as the receive storage word for interrupt notification. A protocol syntax error
will occur if an EM banks is set.
670
Function
Designates the camera for measure-
ment.
Switches to a designated scene No.
Carries out one inspection and outputs
inspection results to the video monitor.
Changes the inspection character string
of a designated inspection area No. to a
designated character string.
Decreases the display camera No. by 1.
Increases the display camera No. by 1.
Modifies the binary levels (upper limit
and lower limit values) of a designated
window number No.
Resets the F200/F300.
Decreases the scene No. by 1.
Increases the scene No. by 1.
Terminates the measurement and
returns to the home menu.
Sets and executes commands that are
otherwise not supported.
Sets and executes commands that are
otherwise not supported.
Set the constant 0000 for the 3rd operand (S).
Set the constant 0000 for the 4th operand (D).
Appendix O
Ladder interface
Send word
Receive word
allocation
allocation
Yes
No
Yes
No
No
No
Yes
No
No
No
No
No
Yes
No
No
No
No
No
No
No
Yes
No
No
No
Yes
No
Yes
Yes
Notes