3Z4L Laser Micrometer Protocol
Measurement Condition Release (4000-series)
(Sequence No. 432 (Hex 01B0))
This sequence clears the measurement conditions that have been set.
Send Data Word Allocation (3rd Operand of PMCR(260))
The send data word allocation is similar to that of sequence No. 431 (Measurement Condition Setting). How-
ever, only the setting Yes/No flags at +19 to +24 from the send data leading word can be used.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note 1. The following conditions are used when the measurement conditions are released: Segment be-
comes 1 and the measurement interval becomes 1.
2. The following settings cannot be cleared separately using this sequence. They all must be cleared at
the same time.
Lower limit, Upper limit
Data output conditions, Scheduled print timer
The scale (SCL) and data output timer (PRT) cannot be cleared.
3. This sequence can be used for the 3Z4L-4000 Series only when pin 8 on DIP switch SW2 is turned
ON.
Measurement Condition List Request (4000-series)
(Sequence No. 433 (Hex 01B1))
This sequence requests the measurement condition settings that have been set and other settings.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
Receive data
+0
storage words
+1
+2
+3
+4
+5
+6
+7
+8
+9
+10
+11
+12
+13
+14
+15
+16
+17
+18
Number of receive data words
(Undefined)
(Undefined)
Decimal portion
Integer portion
(Undefined)
(Undefined)
Sign
Decimal portion
Integer portion
(Undefined)
(Undefined)
Sign
Decimal portion
Integer portion
(Undefined)
(Undefined)
Sign
(Undefined)
(Undefined)
(Undefined)
(Undefined)
Data output timer (BCD 3 digits)
(Undefined)
Segment number (SG)
Measurement interval number (M)
Lower limit value (LL)
Upper limit value (LH)
Reference value (REF)
Analog output scale number (SCL)
Forced zero number (ZERO+)
Data output condition (PR)
(PRT)
Number of seconds for latch timer (RLT)
Appendix N
661