Omron SYSMAC CS1W-SCB41-V1 Operation Manual page 389

Sysmac cs series; sysmac cj series. serial communications boards and serial communications units
Table of Contents

Advertisement

Introduction
D: Receive Data Word Allocation (4th Operand)
Standard System Protocols
Protocol name
CompoWay/F Master (See note.)
Host Link C-mode Command Mas-
ter (See note.)
Host Link FINS Command Master
(See note.)
Mitsubishi Computer Link Master
(A-compatible, 1C frame, model 1)
(See note.)
E5@K Digital Controller Read
E5@K Digital Controller Write
E5ZE Temperature Controller
Read
E5ZE Temperature Controller
Write
E5@J Temperature Controller
ES100@ Controller
Digital Panel Meter
V500/V520 Bar Code Reader
3Z4L Laser Micrometer
F200/F300/F350 Visual Inspec-
tion Systems
360
Receive data
Number of receive data words
+0
storage words
+1
+2
Offset
Contents (data format)
D+0
Number of receive data words
(4 digits Hex)
D+1
Response code (4 digits Hex)
D+2
Receive data (4-digit Hex)
on
The following 16 standard system protocols are provided with the CX-Proto-
col, Serial Communications Boards, and Serial Communications Unit.
Protocol for sending CompoWay/F commands as a Master to OMRON CompoWay/F
slave components and receiving responses.
Protocol for sending C-mode (Host Link) commands to OMRON C-series or CS/CJ-
series PLCs used as slaves and receiving responses.
Protocol for sending Host Link FINS commands to OMRON CS/CJ-series or CVM1/
CV-series PLCs used as slaves and receiving responses.
Protocol for sending Computer Link commands to Mitsubishi PLCs (Sequencer CPU)
used as slaves and receiving responses.
Protocol for controlling an E5@K Digital Controller via the Communications Board.
Procedures for reading the MV the operating parameter settings
Protocol for controlling an E5@K Digital Controller via the Communications Board.
Procedures for writing set points and operating parameters.
Protocol for controlling an E5ZE Temperature Controller via the Communications
Board. Procedures for reading measured temperature and operating parameter set-
tings.
Protocol for controlling an E5ZE Temperature Controller via the Communications
Board. Procedures for writing control temperatures and operating parameters.
Protocol for controlling a E5@J Temperature Controller via the Communications
Board. Procedures for writing set points, reading output amounts, and reading/writing
operating parameters.
Protocol for controlling an ES100@ Controller via the Communications Board. Proce-
dures for writing adjustment parameters, reading operation amounts, and writing/
reading operating parameters.
Protocol for controlling a Digital Panel Meter via the Communications Board. Proce-
dures for writing comparison values and reading display values are set.
Protocol for controlling a Bar Code Reader via the Communications Board. Proce-
dures for controlling the Bar Code Reader in remote mode, reading the data that has
been read by the Bar Code Reader, and reading/writing operating parameters.
Protocol for controlling a Laser Micrometer via the Communications Board. Proce-
dures for controlling the Laser Micrometer in remote mode, reading measured data,
and writing/reading operating parameters.
Protocol for controlling a Visual Inspection System via the Communications Board.
Procedures for controlling the Visual Inspection System in remote mode, reading
measured values, and writing/reading operating parameters.
Response code
Receive data
0003 to 00FA Hex (3 to 250 decimal)
The response code will be stored in hexa-
decimal form.
The data from just after the response code
until just before the ETX will be converted
from ASCII to hexadecimal and stored here.
Function
Appendix A
Data

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents