Functions Added in the Unit Version 1.2 Upgrade
Item
Enhanced
Link word specification data
protocol
exchange timing
macro func-
tions
Reception buffer processing
for PMCR(260) instruction
execution (immediately
before communications
sequence execution)
Baud rate for protocol macro
mode
Standard sys-
Host Link C-mode Command
tem protocol
Master
Host Link FINS Command
Master
Mitsubishi Computer Link
Master (A-compatible, 1C
frame, model 1)
CompoWay/F Master
xxx
Earlier versions
(pre-Ver.1.2)
On-request I/O
Continuous I/O refreshing (selected in DM Area
refreshing only
settings) is supported in addition to the on-request
(request to refresh
I/O refreshing available in earlier models.
sent to CPU Unit at
Continuous I/O refreshing is performed from the
every send/receive
CPU Unit during protocol macro execution, regard-
command execution,
less of requests from the Board/Unit, and data in
and data exchanged
the Board/Unit is accessed during send/receive
during I/O refresh)
command execution. When the send command is
executed with this method, the actual message can
In this method, after
be sent immediately.
the send command is
executed, a delay
occurs before the
actual message is
sent.
Clearing to zero only
Select to clear or hold the contents of the reception
buffer during full-duplex communications (set in the
allocation DM Area).
This enables the data in the reception buffer
received in the previous communications sequence
to be held after switching the communications
sequence during full-duplex communications.
38,400 bps max.
57,600 bps supported (115,200 bps not supported)
(57,600 bps not sup-
ported)
None (protocols must
Provided
be created using CX-
A Host Link Master can
Protocol)
be used to easily access
the Host Link slave PLC
(e.g., A PLC slave on a
moving body can be
accessed via a WM-
series Wireless Modem
in a Host Link.)
Provided
Computer Link commands can be used to access a
Mitsubishi PLC (Sequencer CPU Module) slave.
---
Communications sequences with different send
and receive protocols are provided by using send/
receive commands with ASCII conversion.
The communications sequences have been
expanded to include CompoWay/F commands
such as VARIABLE AREA READ/WRITE and
OPERATING INSTRUCTIONS.
Unit version 1.2 or later
Host Link C-mode com-
mands can be used to
access a C-series or CS/
CJ-series PLC slave.
Host Link FINS com-
mands can be used to
access a CS/CJ-series
or CVM1/CV-series PLC
slave.
This protocol can also
be used to access slave
PLCs on the network.
9