Auxiliary Area and CIO Area Allocations

8-2-2
Setup Area Contents
Boards
(CS Series only)
Port 1
D32000
D32001
D32006
Serial Communications
Mode
Maximum 1:N NT Links
Unit No.
8-3
Auxiliary Area and CIO Area Allocations
DM Area
Unit
(CS/CJ Series)
Port 2
Port 1
Port 2
D32010
m
m + 10
D32011
m + 1
m + 11
D32016
m + 6
m + 16
Note With CS-series, a high-speed NT Link is available only with Serial Communi-
cations Boards or Serial Communications Units manufactured on or after
December 20th, 1999. With earlier models, only standard NT Link is available.
Lot No: 20Z9
Manufactured on December 20th, 1999
The year is indicated with the last digit. In this case, "9" indicates "1999."
Month of manufacture. October, November, and December are indicated
with X, Y, and Z respectively. In this case, the month is "December."
Day of manufacture. In this example, the day is "20."
NT31/631(C)-V2 are the only PTs for which high-speed NT link is supported.
Except for the baud rate, the 1:N NT Link communications specifications are
fixed. Therefore, the port settings, start bits, stop bits, and parity need not be
set. Even if they are set, they are ignored.
Set the serial communications mode to 2 Hex to use 1:N NT Link mode.
With 1:N NT Links, up to eight Programmable Terminals (PTs) can be con-
nected. The highest connected unit number is set here.
This section describes the bits and words used by the Serial Communications
Board and Serial Communications Units in the Auxiliary Area and the Status
Area allocated in the CIO Area. The Software Switches allocated in the CIO
Area are not used for 1:N NT Links.
Bit
15
Port settings
12 to 14
Reserved
08 to 11
Serial communications mode: Always 2 Hex (1:N
NT Link)
05 to 07
Reserved
04
Start bits
03
Data length
02
Stop bits
01
Parity
00
Parity
04 to 15
Reserved
00 to 03
Baud rate (bps)
0 to 9 Hex: Standard NT Link
A Hex: High-speed NT Link (See note.)
03 to 15
Reserved
00 to 02
1:N NT Link
Section 8-3
m = D30000 + 100 × unit number
Setting contents
Setting not required.
Setting not required.
Setting not required.
Setting not required.
Setting not required.
Setting not required.
Maximum unit number: 0 to
7 hex
267