Omron SYSMAC CS1W-SCB41-V1 Operation Manual page 69

Sysmac cs series; sysmac cj series. serial communications boards and serial communications units
Table of Contents

Advertisement

Comparison to Previous Products
Item
Send/receive messages
Interrupt notification function
Simple Backup Function
40
Reception length
Error check codes
C200HX/HG/HE
No check.
No LRC2 or SUM1 checks.
Supported.
None
Section 1-7
CS/CJ
The length of data set in the
expected reception message
will be fetched from the recep-
tion buffer as the message.
LRC2 and SUM1 supported.
Boards: Supported.
Units:
Not supported.
The CPU Unit's Simple Backup
Function can be used to backup
the Protocol Macro data in the
Serial Communications
Board/Unit to the CPU Unit's
Memory Card. The backed-up
data can be restored or com-
pared.
(When a CS1-H CPU Unit is
being used, this function is sup-
ported by the CS1W-SCB21-
V1, CS1W-SCB41-V1, CS1W-
SCU21-V1, and CS1W-SCU31-
V1. When a CJ1-H CPU Unit is
being used, this function is sup-
ported by the CJ1W-SCU21(-
V1), CJ1W-SCU31-V1 and
CJ1W-SCU41(-V1).)